Picas / Signalog 6000 Measuring Amplifiers
Key features
- 2 channel 5 kHz carrier frequency amplfier with 2 kHz bandwidth (CA2CF card) with galvanic isolation between sensor and amplifier
- 4 channel DC amplifier for DC, potentiometric sensors and thermocouples (CA4AI card )
- Combine CF and DC amplifiers in one system
- 20,000 measurements/s using the PB61000 high speed controller
- Operation via PC or by the dedicated pushbuttons and 5 digit display at the front
- Communication via USB, RS232 or RS485
- Extendable to 128 channels by using the RS-485 communication port
- Full software control by Active-X controls
- Simple 3-step operation to obtain correct measuring
CA2CF: 2 channel carrier amplifier
The CA2CF has been primarily developed for the conditioning of straingauges and sensors based on the straingauge principle. PICAS (Peekel Instruments Compact Amplifier System) provides built-in precision resistors (120 and 350 W) to enable connection of single and double strain gauges. Each channel has a provision to compensate cable losses.
Features of the CA2CF card:- measuring ranges selectable 100 µV/V...1V/V
- each channel has an analog output which can be calibrated
- bandwidth from 2kHz (-3dB) @ 5kHz carrier frequency
- 7th-order Butterworth (-42dB/Octave) lowpass filter
- automatic nullbalance to 65mV/V at the amplifier's input
- galvanic isolation between sensor and amplifier through transformers
- high common mode rejection factor >120dB
- simple operation with multi-lingual display
- well-proven analog technology combined with state-fo-the-art digital technology
The CA2CF to measure:
- straingauges in ¼-, ½- and 1/1 bridge configuration
- loadcells, pressure- and acceleration transducers
- inductive displacement transducers (LVDT´s)
- capacitive sensors
Why use carrier frequency?
- high sensitivity
- high long-term stability
- high noise reduction
- immune to thermo-electric voltages
- use of transformers provides galvanic isolation
CA4AI: 4 channel DC amplifier
The 4 channel DC input card is the latest addition to the PICAS/SIGNALOG 6000 program. With this card one can combine strain gauge measurements based on CF technology with DC measurements for thermocouples, Pt100 sensors, current etc.
Features of the CA4AI card:
-
Selectable ranges
- DC (Ri=10MW): ± 10V, ± 5V, ± 2V, ±0.5V, ± 100mV, ± 50mV, ± 20mV
- Current (Ri=100W): ± 100mA, ,± 50mA, ± 10mA and ± 5mA
- Resistance: 7.5 kW, 2 kW, 500 W, 100 W
- Resitant thermosensors Pt-100 and Pt-1000
- Thermocouples type: B, E, J, K, N, R, S, T
- Bandwidth 10 Hz
- Supply for external sensors: 1 x 24VDC @ 80 mA
High speed controller card PB6100 Processor
-
Common info:
- 16 bit micro with 16 bit A/D converter
- Measurement speeds up to 20,000/s 4 measurement groups with individual speeds
-
Communication:
- USB PC communication (configuration, data-storage, reading)
- RS232
- RS485 to communicate with other PICAS/SIGNALOG systems
-
Datalogger function
- 2 Mb SRAM voor storage of about 50,000 measurement values
- Real time clock
- Storage of various data-sets
Download Picas, Signalog and Signasoft 6000 documentation and software